DETERMINING THE EXTINGUISHING TIME OF A CLASS B FIRE USING A SEGWAY-BASED WATER SPRAY FIRE EXTINGUISHING CONTROL SYSTEM

Authors

  • Y. Abramov Національний університет цивільного захисту України
  • V. Kolomiiets Національний університет цивільного захисту України
  • V. Sobyna Національний університет цивільного захисту України

DOI:

https://doi.org/10.33042/2522-1809-2025-1-189-384-389

Keywords:

Class B fire, extinguishing time, sprayed water

Abstract

A formalized option is provided for determining the time to extinguish a class B fire with the definition of a spray water fire extinguishing control system, based on the use of its transient function at a level of 10.0% relative to its maximum value. To determine the transient function of the sigma-based fire extinguishing control system for sprayed water, its transfer function is used, which is represented by a fractionally rational function with a fourth-order Hurwitz polynomial and in which the delay is taken into account as a second-order polynomial. A mathematical model for the error of the transient function of the sigma-based fire extinguishing control system for sprayed water due to errors in the parameters of its functional elements has been obtained. For the characteristic values of the parameters of the sigway-based fire extinguishing control system, estimates of the extinguishing time of a class B fire were obtained and it was shown that with the same errors in the parameters of this system, which are equal to 10.0%, there is an error in determining the extinguishing time, which is 18.3%. The presence of such an error in determining the time to extinguish a fire requires an increase in water consumption by 1.18 times. Taking into account the finite water reserves at the mobile fire unit, there is a need to obtain information on the value of the parameters of the fire extinguishing control system. The paper presents the features of determining (controlling) the parameters of the fire extinguishing system with sprayed water based on sigma, which include - operator parameters are determined using simulators; - class B fire parameters are determined using model fire foci, in which the liquid of the technological process of the object where a fire may occur is used as a burning liquid; - the properties of the area where sprayed water is delivered to the fire are taken into account (in the form of a delay time, which is included as an additive component of the delay time of the fire extinguishing control system).

References

Harshad Shrigondekar, Arindrajit Chowdhury, S.V. Prabhu, Characterization of solid-cone simplex mist nozzles, Fire Safety Journal V. 111, 2020, 102936, ISSN 0379-7112, https://doi.org/10.1016/j.firesaf.2019.102936.

Jeong C.S., Lee C.Y. Experimental investigation on spray characteristics of twin-fluid nozzle for water mist and its heptane pool fire extinguishing performance// Process Safety and Environmental Protection.2021 Vol. 148, Pages 724-736. Doi: https://doi.org/10.1016/j.psep.2021.01.037

Shrigondekar, H., Chowdhury, A. & Prabhu, S.V. Performance by Various Water Mist Nozzles in Extinguishing Liquid Pool Fires. Fire Technol 57, 2553–2581 (2021). https://doi.org/10.1007/s10694-021-01130-0

Lu,D. Tan W., Zhu G., Liu L., Gasoline fire extinguishing by 0.7 MPa water mist with multicomponent additives driven by CO2, Process Safety and Environmental Protection, Volume 129, 2019, Pages 168-175, ISSN 0957-5820, https://doi.org/10.1016/j.psep.2019.07.002.

Dasgotra A., Rangarajan G., Tauseef S.M. CFD-based study and analysis on the effectiveness of water mist in interacting pool fire suppression. Process Safety and Environmental Protection. V.152.2021.P.614-629. https://doi.org/10.1016/j.psep.2021.06.033

Yang Liu, Peng Chen, Zhixi Fu, Jiayan Li, Ruibang Sun, Xu Zhai. The investigation of the water mist suppression pool fire process's flame expansion characteristics// Journal of Loss Prevention in the Process Industries.2023. vol. 81. P. 104927. Doi: https://doi.org/10.1016// j.jlp.2022. 104927

Liu, T.; Yin, X.-Y.; Liu, Y.-C.; Tang, Y.; Huang, A.-C.; Dong, X.-L.; Liu, Y.-J. Influence of Water Mist Temperature Approach on Fire Extinguishing Effect of Different Pool Fires. Processes 2022, 10,1549. https://doi.org/10.3390/ pr10081549.

Котов А.Г. Пожежогасіння та системи безпеки. Київ. 2010. 278 с.

Шевчук В.Г., Поліщук Д.Д. Фізичні основи пожежовибухонебезпеки. Одеса. 2010. 244 с

Абрамов, Ю.О, Коломієць, В.С., Собина, В.О. Структурний синтез мобільної пожежної установки для гасіння пожеж класу В. Ю.О. Абрамов, , В.С. Коломієць, В.О. Собина. Комунальне господарство міст. Вип. 185. Т. 4. 2024., с. 153–158. https://doi.org/10.33042/2522-1809-2024-4-185-153-158

Абрамов Ю.О., Собина В.О., Сошинський О.І. Еволюція автономних мобільних засобів пожежогасіння/. Комунальне господарство міст. – Ввип. 177. – Т.3 – 2023. – с. 147-152 https://doi.org/10.33042/2522-1809-2023-3-177-147-152

Пристрій для визначення характеристик оператора мобільної пожежної установки: Патент Україна 155126: МПК А62С 37/00, А61В5/16, G09В9/02/ Абрамов Ю.О., Собина В.О., Демент М.О., Закора О.В., заяв. та патентовласник НУЦЗУ. - № 202303780; заяв. 7.08.2023; опубл. 07.01.2024; Бюл. № 3.

Kolomiiets V., Abramov Y., Basmanov O., Sobyna V., Sokolov D. Determining the dynamic characteristics of a class b fire in the case of extinguishing by water spray. Eastern-European Journal of Enterprise Technologies. 2023. V. 6/10 (126) DOI: 10.15587/1729-4061.2023.292767

Тарахно О.В. Фізико-хімічні основи використання води в пожежній службі. Харків. 2004. 252 с.

Published

2025-04-02

How to Cite

Abramov, Y., Kolomiiets, V., & Sobyna, V. (2025). DETERMINING THE EXTINGUISHING TIME OF A CLASS B FIRE USING A SEGWAY-BASED WATER SPRAY FIRE EXTINGUISHING CONTROL SYSTEM. Municipal Economy of Cities, 1(189), 384–389. https://doi.org/10.33042/2522-1809-2025-1-189-384-389

Issue

Section

статьи